- WINDOW
- 30s pre + 10s
- LAB CAP
- 120s / 512 MB
- ROUND TRIP
- absorbed
- USER PLANE
- excluded
- 5G signalling / anomaly
- HOLD / CUT window export
- failure / UDM fault
Starting capture after an alert misses the root cause. Every host keeps a rolling buffer sized to: before + after + longest trigger delay + export lag + margin.
With 30 s before, 10 s after, 20 s fan-out delay, 4 s export lag, and a 10 s margin (74 s, capped at 120 s in lab), even a late fan-out request still finds the pre-fault packets intact in RAM (~512 MB cap at 20 Mbit/s signalling).
Buffer capacity budget
- Pre-fault + post-fault window → 30s before + 10s after
- Cross-host trigger & export lag → +20s delay + 4s export
- Clock skew & safety margin → +10s (lab configured to 120s)